A GPU-based multi-criteria optimization algorithm for HDR brachytherapy.

In conclusion, two ultra-fast and robust multi-criteria optimization algorithms were implemented for HDR prostate brachytherapy. A large-scale comparison against physician approved clinical plans showed that treatment plan quality could be improved and plan generation time could be significantly reduced with the proposed GPU-based MCO algorithms. PMID: 30970341 [PubMed - as supplied by publisher]
Source: Physics in Medicine and Biology - Category: Physics Authors: Tags: Phys Med Biol Source Type: research