Compared Efficacy of Four Preoxygenation Methods for Intubation in the ICU: Retrospective Analysis of McGrath Mac Videolaryngoscope Versus Macintosh Laryngoscope (MACMAN) Trial Data

Objectives: Severe hypoxemia is the most common serious adverse event during endotracheal intubation. Preoxygenation is performed routinely as a preventive measure. The relative efficacy of the various available preoxygenation devices is unclear. Here, our objective was to assess associations between preoxygenation devices and pulse oximetry values during endotracheal intubation. Design: Post hoc analysis of data from a multicenter randomized controlled superiority trial (McGrath Mac Videolaryngoscope Versus Macintosh Laryngoscope [MACMAN]) comparing videolaryngoscopy to Macintosh laryngoscopy for endotracheal intubation in critical care. Setting: Seven French ICUs. Patients: Three-hundred nineteen of the 371 critically ill adults requiring endotracheal intubation who were included in the MACMAN trial. Interventions: None. Measurements and Main Results: Minimal pulse oximetry value during endotracheal intubation was the primary endpoint. We also sought risk factors for pulse oximetry below 90%. Of 319 patients, 157 (49%) had bag-valve-mask, 71 (22%) noninvasive ventilation, 71 (22%) non-rebreathing mask, and 20 (7%) high-flow nasal oxygen for preoxygenation. Factors independently associated with minimal pulse oximetry value were the Simplified Acute Physiology Score II severity score (p = 0.03), baseline pulse oximetry (p
Source: Critical Care Medicine - Category: Emergency Medicine Tags: Online Clinical Investigations Source Type: research