Validation and Critical Evaluation of the Effective Arterial Elastance in Critically Ill Patients

Objectives: First, to validate bedside estimates of effective arterial elastance = end-systolic pressure/stroke volume in critically ill patients. Second, to document the added value of effective arterial elastance, which is increasingly used as an index of left ventricular afterload. Design: Prospective study. Setting: Medical ICU. Patients: Fifty hemodynamically stable and spontaneously breathing patients equipped with a femoral (n = 21) or radial (n = 29) catheter were entered in a “comparison” study. Thirty ventilated patients with invasive hemodynamic monitoring (PiCCO-2; Pulsion Medical Systems, Feldkirchen, Germany), in whom fluid administration was planned were entered in a “ dynamic” study. Interventions: In the “dynamic” study, data were obtained before/after a 500 mL saline administration. Measurements and Main Results: According to the “cardiocentric” view, end-systolic pressure was considered the classic index of left ventricular afterload. End-systolic pressure was calculated as 0.9 × systolic arterial pressure at the carotid, femoral, and radial artery level. In the “comparison” study, carotid tonometry allowed the calculation of the reference effective arterial elastance value (1.73 ± 0.62 mm Hg/mL). The femoral estimate of effective arterial elastance was more accurate and precise than the radial estimate. In the “dynamic” study, fluid administration increased stroke volume and end-systolic pressure, whereas ...
Source: Critical Care Medicine - Category: Emergency Medicine Tags: Online Clinical Investigations Source Type: research