Design and Implementation of High Power LED Lighting System for Health Care Applications

Conclusion: This manuscript suggests a modified single switch SEPIC LED driver for 48V output operated healthcare equipment. Simulation study of this driver shows the better performance. In order to analyze the performance, a comparative study was conducted by using the classical PI and the novel PI integrated fuzzy controller. Satisfactory results regarding enhanced quality of power, regulated load voltage, quick rise time and settling time were achieved. The source current THD has been reduced to around 1.39% which is less than 5% as per the IEEE-516 prescribed standard and the power factor has been improved to 0.9995 by implementing the fuzzy tuned PI controller. The above results favor the suggested modified SEPIC LED driver for practical healthcare applications.