Low-dose rt-PA may not decrease the incidence of symptomatic intracranial haemorrhage in patients with high risk of symptomatic intracranial haemorrhage.
CONCLUSIONS: Our study suggests that low-dose intravenous rt-PA for high-risk sICH stroke in Chinese patients may not decrease the incidence of sICH, and concomitant with a poor outcome compared to standard-dose rt-PA.
ABBREVIATIONS: rt-PA: recombinant tissue plasminogen activator; AIS: acute ischemic stroke; sICH: symptomatic intracranial haemorrhage.
PMID: 30822264 [PubMed - as supplied by publisher]
Source: Neurological Research - Category: Neurology Tags: Neurol Res Source Type: research