Intraindividual comparison of 68Ga-DOTATATE PET/CT vs. 11C-choline PET/CT in patients with prostate cancer in biochemical relapse: In vivo evaluation of the expression of somatostatin receptors

Conclusions68Ga-DOTATATE PET/CT and 11C-choline PET/CT seem to have a high capacity to detect pathological lesions in the assessment of patients with prostate cancer with biochemical relapse. Further studies are required to test the potential complementary value of these PET/CT techniques, and to evaluate the potential role of 68Ga-DOTATATE for planning somostatin receptor-mediated therapies (177Lu-DOTATATE).ResumenAntecedentes y objetivosComparar prospectivamente la tasa de detección de la PET/TC con 68Ga-DOTATATE versus 11C-colina en pacientes con cáncer de próstata en recaída bioquímica y evaluar in vivo la expresión de receptores de la somatostatina con el fin de planificar terapias dirigidas (177Lu-DOTATATE).Material y métodosAnalizamos prospectivamente 64 pacientes con recaída bioquímica (mediana PSA: 4,25 ng/mL). Se realizó una PET/TC con 11C-colina y otra con 68Ga-DOTATATE. Se midió el SUVmáx en todas las lesiones. Se consideraron como patrón de referencia las imágenes correlativas, histopatología y/o seguimiento clínico y bioquímico.ResultadosLa tasa de detección global por paciente fue del 48,43% para 68Ga-DOTATATE y de 46,87% para 11C-colina. Los resultados fueron concordantes en 53 casos (82,81%). El SUV máximo de la 11C-colina fue significativamente mayor que el correspondiente al 68Ga-DOTATATE para todas las lesiones concordantes (n = 130): 6,17 (1,7-15,5) versus 4,38 (1,37-26,7), mediana (rango), para cada radiotrazador, respec...
Source: Revista Espanola de Medicina Nuclear e Imagen Molecular - Category: Nuclear Medicine Source Type: research