Very affordable post mortem CT angiography kit: feasibility study using immersion pump and 3D printed parts

Publication date: Available online 12 December 2018Source: Journal of Forensic Radiology and ImagingAuthor(s): Wolf Schweitzer, Markus Enders, Michael ThaliAbstractThe high cost of commercial components and parts for post-mortem computed tomography angiography (PMCTA) has resulted in the development of a very low cost PMCTA-kit. It contains ubiquitous parts from hardware stores, and rapid prototyping derived models for 3D-printing. Design specifications have been tested and improved after finite-element modeling. A case study performed in using the final PMCTA kit parts for a PMCTA shows perfect vascular contrast without relevant leaks.
Source: Journal of Forensic Radiology and Imaging - Category: Radiology Source Type: research