Frequent Hemodialysis Fistula Infectious Complications

Conclusions: The rate of buttonhole-related infections was high among patients on frequent hemodialysis and more than 50 times greater than that among patients on CIHD with the stepladder technique. Most bacteremias were due to S. aureus - with serious consequences. The risks and benefits of buttonhole cannulation require individual consideration with careful monitoring, prophylaxis and management.Nephron Extra 2014;4:159-167
Source: Nephron Extra - Category: Urology & Nephrology Source Type: research