Siemens wins FDA nod for Cios Spin mobile 3D C-arm

Siemens (NYSE:SI) Healthineers said today that it won FDA clearance for its Cios Spin mobile C-arm device for intraoperative 3D imaging. The newly cleared Cios Spin produces 3D computed tomography-like imaging for orthopedic, trauma and spinal surgery that Siemens claims can reduce the rate of revisions and need for post-operative CT. The Cios Spin supports both 2D and 3D imaging and can be used for a variety of procedures, including vascular imaging, Siemens said. The system also features NaviLink 3D digital navigation and flat panel detector technology and other software packages. “Siemens Healthineers is proud to offer the Cios Spin, a dynamic new mobile 3D C-arm that illustrates our expertise in mobile X-ray imaging. This system will help our customers improve the quality of patient care using precision medicine as well as reduce the additional costs imposed by revision surgery,” Siemens Healthineers NA surgical solutions VP Robert Dewey said in a press release. Last month, Siemens Healthineers said that it inked a deal with Healthy.io looking to improve home chronic kidney disease monitoring. The post Siemens wins FDA nod for Cios Spin mobile 3D C-arm appeared first on MassDevice.
Source: Mass Device - Category: Medical Devices Authors: Tags: 510(k) Food & Drug Administration (FDA) Imaging Regulatory/Compliance Siemens Healthineers Source Type: news

Related Links:

CONCLUSIONS: IL-6 and CS were significantly associated with 5-year risk of all-cause mortality in CKD patients. Our study suggests an involvement of chronic inflammation linked to coronary artery calcification that is likely to contribute to the cardiovascular mortality in patients with impaired renal function. PMID: 30991230 [PubMed - as supplied by publisher]
Source: Cytokine - Category: Molecular Biology Authors: Tags: Cytokine Source Type: research
Abstract Positron emission tomography combined with computed tomography (PET/CT) is a nuclear imaging technique which provides anatomical and functional information. PET/CT is increasingly used in non-oncological nephrology since conventional radiological approaches after injection of contrast agents are relatively contra-indicated in patients with chronic kidney disease (CKD). PET/CT after i.v. injection of 18F-fluoro-deoxy-glucose (FDG) is not toxic and is characterized by a high sensitivity. The level of irradiation (∼5mSv) is acceptable. CKD does not significantly influence tissue uptake of 18F-FDG. The pu...
Source: Nephrologie and Therapeutique - Category: Urology & Nephrology Authors: Tags: Nephrol Ther Source Type: research
ConclusionsIn this study we observed that in later-stage ADPKD, octreotide-LAR slowed kidney growth and delayed progression to ESRD, in particular in CKD stage 4. Trial registrationClinicalTrials.gov NCT01377246; EudraCT: 2011-000138-12.
Source: PLoS Medicine - Category: Internal Medicine Authors: Source Type: research
ConclusionKSS should be offered in low-risk UTUC when feasible, whereas RNU is the treatment of choice in organ-confined high-risk UTUC. Intravesical recurrence (IVR) is common after RNU, but a single postoperative dose of mitomycin instillation decreases IVR. Endourological management has high local and bladder recurrence rates; however, its effect on CSS or overall survival OS is unclear. RNU is associated with significant risk of chronic kidney disease. Careful selection of patients and risk stratification are mandatory, and patients should be followed according to strict protocols.
Source: World Journal of Urology - Category: Urology & Nephrology Source Type: research
Patients with chronic kidney disease (CKD) have an increased risk of adverse cardiovascular/cerebrovascular events. The aim of this study is to clarify whether stress myocardial perfusion single-photon emission computed tomography (SPECT) could predict cardiovascular/cerebrovascular events. In the Gunma-CKD SPECT Study, a multicenter prospective cohort trial, 311 patients with CKD (estimated glomerular filtration rate #x3c; 60 min/mL/1.73 m2) including 50 patients on hemodialysis underwent stress99mTc-tetrofosmin SPECT for suspected ischemic heart disease and were followed for 2 years. The primary endpoint was the occurren...
Source: Cardiology - Category: Cardiology Source Type: research
nek M Abstract BACKGROUND: Determining a prognosis based on ischemia detection, using myocardial perfusion imaging by single photon emission computed tomography (MPI-SPECT), can be challenging in patients with multiple affected coronary arteries. AIM: To examine the outcomes of MPI-SPECT combined with the coronary artery calcium score (CACS) to identify predictors of adverse cardiac events (CEs) in a group of patients for whom ischemia detection may be difficult using MPI-SPECT. METHODS: The study group included 195 patients who had a history of chronic kidney disease, suspicious ischemic cardiomyopathy,...
Source: Kardiologia Polska - Category: Cardiology Authors: Tags: Kardiol Pol Source Type: research
Abstract BACKGROUND: High-resolution peripheral quantitative computed tomography (HR-pQCT) evaluates different components of bone fragility. The positioning and length of the region of interest (ROI) in growing populations remain to be defined. METHODS: Using HR-pQCT at the ultradistal tibia, we compared a single-center cohort of 28 teenagers with chronic kidney disease (CKD) at a median age of 13.6 (range, 10.2-19.9) years to local age-, gender-, and puberty-matched healthy peers. Because of the potential impact of short stature, bone parameters were assessed on two different leg-length-adjusted ROIs in comp...
Source: Archives de Pediatrie - Category: Pediatrics Authors: Tags: Arch Pediatr Source Type: research
This report describes a massive pleural effusion that led to the discovery of subclavian artery rupture causing hemodynamic shock. Hemodynamic instability in this patient was caused by hypovolemic and obstructive shock, with a pleural perfusion caused by subclavian artery rupture. Monitoring via transesophageal echocardiography during the procedure enabled early discovery of the massive pleural effusion. Subsequent covered stent implantation stabilized the subclavian artery rupture, and the patient became hemodynamically stable. As subclavian artery rupture can occur during trans-subclavian TAVI, the presence of calcificat...
Source: Journal of Cardiology Cases - Category: Cardiology Source Type: research
Postcontrast acute kidney injury (AKI) occurs more frequently in patients with lower estimated glomerular filtration rate. We hypothesized that postcontrast AKI in chronic kidney disease (CKD) patients with distinct risk factors might be associated with accelerated renal progression. We undertook this retrospective cohort study to develop and validate a risk scoring model for predicting renal progression. In a development dataset, 18,278 contrast-enhanced CT scans were performed in 9097 patients with CKD (estimated glomerular filtration rate [eGFR] 
Source: Medicine - Category: Internal Medicine Tags: Research Article: Observational Study Source Type: research
This is the first reported case of necrotizing nasal and sinus herpes infection with orbital involvement. A 94-year-old male with a past medical history of hypertension, congestive heart failure, and chronic kidney disease presented with necrotic nasal cellulitis and a red left eye with blurry vision. Onset was 2 weeks prior with an upper lip fever blister. He was admitted to medicine and started on antimicrobials. Maxillofacial computed tomography scan revealed pansinusitis with involvement of bilateral medial orbital walls. Initial nasal biopsy was negative. Repeat biopsy was positive for herpes simplex virus 1. His nose...
Source: Ophthalmic Plastic and Reconstructive Surgery - Category: Opthalmology Tags: Case Reports Source Type: research
More News: Chronic Kidney Disease | CT Scan | Orthopaedics | Urology & Nephrology