Mismatch Negativity in Children: Reference Values

Conclusion Using the described protocol, the mean latency value of MMN was 184.0 ms for RE and 182.9 ms for LE, and the amplitude was 5.05 μV and 5.56 μV for the left and right ears, respective. [...] Thieme Revinter Publicações Ltda Rio de Janeiro, BrazilArticle in Thieme eJournals: Table of contents  |  Abstract  |  open access Full text
Source: International Archives of Otorhinolaryngology - Category: ENT & OMF Authors: Tags: Original Research Source Type: research