Experimental comparative study of thrombogenicity of two differently luminal heparinized ePTFE vascular prosthetics

Conclusion; Based on patency data alone, no significant difference between these grafts were found. In accordance, heparin activity analysis showed no difference between the grafts. The model itself, proved easily implementable, and provides many possibilities for future studies, though some adjustments should be made to improve survival.
Source: Annals of Medicine and Surgery - Category: General Medicine Source Type: research