Accurate measurement of main aerosol constituents from heated tobacco products (HTPs): Implications for a fundamentally different aerosol

In this study we have evaluated the suitability of ISO 4387 Standard to be adapted for quantifying main aerosol constituents for HTP aerosol. HTP emissions have much higher levels of water and humectants (e.g., glycerol) in dynamic equilibria between gaseous and particulate phases. Several modifications to ISO 4387 Standard on aerosol collection were tested to improve the accuracy and reliability of aerosol capturing, with minimal deviation to the standard method. The proposed modifications are readily adoptable by laboratories already practicing the Standard for cigarette smoke analyses. Taking collectively with other available aerosol chemistry and biological results on HTPs in the literature, they show a fundamentally different aerosol in HTPs and call for a category-specific product standards and terminology.
Source: Regulatory Toxicology and Pharmacology - Category: Toxicology Source Type: research