Balloon-Anchored CoKatte ® for Successfully Delivering Balloons for an Occluded Anomalous Right Coronary Artery

This report describes the method we used. Although, delivering the balloon was difficult in short of the guiding catheter's backup force, we finally succeeded by using one more guiding catheter and the balloon-anchored CoKatte®, a novel, straight 4.5-French child catheter, to strengthen the backup force. [...] Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.Article in Thieme eJournals: Table of contents  |  Abstract  |  Full text
Source: International Journal of Angiology - Category: Cardiology Authors: Tags: Case Report Source Type: research