The multigaussian method: a new approach to mitigating spatial heterogeneities with multichannel radiochromic film dosimetry.

In this study, the abilities of various single channel and multichannel methods to reduce spatial heterogeneities, with and without scanning before irradiation, were tested. Red, green and blue single channel models, two additive channel independent perturbation (CHIP) models and two multiplicative CHIP models were compared with the Multigaussian method. The Multigaussian method is a new approach to multichannel dosimetry, based on experimental findings. It assumes that the probability density function of the response vector formed by the pixel values of the different color channels, including irradiated and non-irradiated scans, follows a multivariate Gaussian distribution. The Multigaussian method provided more accurate doses than the other models under comparison, especially when incorporating the information of the film prior to irradiation. The relative dose differences between reference doses measured with MatriXX and film doses were examined. After applying inter-scan and lateral corrections, the lowest mean absolute errors were 0.8% and 1.0% for the Multigaussian method with and without the information of the scan before irradiation, respectively. Followed by the uniform multiplicative CHIP and red single channel models, using pixel values and net optical density, respectively, both with 1.1%. PMID: 30101754 [PubMed - as supplied by publisher]
Source: Physics in Medicine and Biology - Category: Physics Authors: Tags: Phys Med Biol Source Type: research
More News: Biology | Men | PET Scan | Physics | Study