Transducer impulse response correction for a deconvolution derived ultrasound transit time spectrum.

Transducer impulse response correction for a deconvolution derived ultrasound transit time spectrum. Phys Med Biol. 2018 Aug 08;: Authors: Al-Qahtani SM, Wille ML, Langton CM Abstract Propagation of ultrasound through a complex composite sample may exhibit phase interference between two or more sonic-rays if differences in transit time are less than the pulse length. The transit time spectrum of a test sample, equivalent to its impulse response, was derived through active-set deconvolution of ultrasound signals with, and without, the test sample. The aim of this study was to test the hypothesis that in cases where only the transmit ultrasound transducer's digitally-coded excitation signal is available, hence not the input ultrasound signal without the test sample, incorporation of the Transducer Impulse Response (TIR) may increase both accuracy and precision of ultrasound transit time spectroscopy. A digital 1 MHz sinusoid signal was used to create an ultrasound pulse that was propagated through a 5 step-wedge acrylic sample immersed in water. Transit time spectra were obtained through deconvolution utilising an ultrasound input signal, along with a digital input signal, with and without incorporation of the transducer impulse response. Incorporation of the transducer impulse response reduced a quantitative measure of noise-to-signal ratio by a factor of 12. 
 
 The paper has demonstrated the potential for increased a...