Clinical research: remote magnetic navigation vs. manually controlled catheter ablation of right ventricular outflow tract arrhythmias: a retrospective study

ConclusionRight ventricular outflow tract arrhythmia ablations were performed using half of fluoroscopic times with Stereotaxis platform RMN compared to manual approach. Acute and chronic success rates as well as complication rates were not significantly different.
Source: Europace - Category: Cardiology Source Type: research