Three-Dimensional Strain Measurements of a Tubular Elastic Model Using Tomographic Particle Image Velocimetry

This study ’s scope was to measure strain in deformed tubular elastic mock vessels using tomographic particle image velocimetry (tomo-PIV), and to show the applicability of this measurement method by comparing the results with data derived from a finite element analysis (FEA). Strain distribution was calcula ted from the displacement distribution, which in turn was measured by tracking fluorescent 13 μm particles in a transparent tubular elastic model using tomo-PIV. The von Mises strain distribution was calculated for a model whose inner diameter was subjected to a pressure load, because of which it expanded from 25 to 27.5  mm, adjusting to the diameter change of a human aorta during heartbeat. An FEA simulating the experiment was also conducted. Three-dimensional strain was successfully measured by using the tomo-PIV method. The radial strain distribution in the model linearly decreased outward (from the its inner t o its outer side), and the result was consistent with the data obtained from the FEA. The mean von Mises strain measured using tomo-PIV was comparable with that obtained from the FEA (tomo-PIV: 0.155, FEA: 0.156). This study demonstrates the feasibility of utilizing tomo-PIV to quantitatively assess the three-dimensional strain induced in largely deformed elastic models.
Source: Cardiovascular Engineering and Technology - Category: Cardiology Source Type: research