Appropriate angled-tip front width facilitates tracheal tube introducer placement in difficult-to-displace epiglottis situations

Amitabh Dutta, Manish Gupta, Prabhat Kumar Choudhary, Jayashree SoodIndian Journal of Anaesthesia 2018 62(3):229-232 Tracheal tube introducers (TTIs) are a useful aid to a conventional laryngoscopy-intubation method of upper airway access in adults. However, even when TTIs are used, successful tracheal intubation is not guaranteed. Apart from suboptimal practice proficiency and unavailability of the complete repertoire of TTI, the physical attributes of the TTI have a role to play. Our report on the management of two cases highlights the importance of selecting a TTI with appropriate angled tip characteristics to facilitate successful guided intubation.
Source: Indian Journal of Anaesthesia - Category: Anesthesiology Authors: Source Type: research