Monitoring of Myocutaneous Flaps by Measuring Capillary Glucose and Lactate Levels: Experimental Study

Introduction In surgery, certain defects require reconstruction with a microsurgical flap. The free flap failure rate varies between 2% and 5%. Vascular thrombosis is the most frequent complication and represents 15% to 73% of failures. The success rate of salvage therapy is greater when salvage surgery is early. Currently, clinical monitoring is the criterion standard but many noninvasive or minimally invasive techniques have been developed to improve early diagnosis of complications of vascular thrombosis. The aim of our experimental study was to compare clinical assessments with measurements of capillary glycemia and lactatemia during the monitoring of free flaps. Materials and Methods Myocutaneous latissimus dorsi flaps with skin paddles were created in pigs under general anesthesia. For each animal, 2 flaps were created (right and left) using the same technique. Four groups were made: group 1 (no flap ligation: control group), group 2 (flap with permanent ligation of the artery), group 3 (flap with permanent ligation of the two veins), group 4 (flap with transient ligation of the artery and 2 veins for 1 hour). The postoperative monitoring protocol consisted of monitoring the clinical, biological (glucose and lactate), and histological parameters. Results Eight animals were operated on and sixteen flaps were created. Each flap was clinically and biologically tested 25 times. Clinical, biological, and histological monitoring showed significant variations between t...
Source: Annals of Plastic Surgery - Category: Cosmetic Surgery Tags: Research Source Type: research