Impact of an Ultrasonically Activated Device in Robot-Assisted Distal Gastrectomy

This study therefore assessed the effect of ultrasonically activated device use on procedural times and on other early surgical outcomes. Methods Consecutive patients (N = 42) who underwent robot-assisted distal gastrectomy for gastric cancer were included. Clinicopathological characteristics and early surgical outcomes were compared between robotic-assisted gastrectomy procedures using an ultrasonically activated device (U group, n = 21) and those without it (NU group, n = 21). Results There were no significant differences in patient characteristics between the groups; however, the median operation time was significantly less in the U group than in the NU group (291 vs 351 minutes, P = 0.006). In detail, the median duration of console time until dividing the duodenum was less in the U group (70 vs 102 minutes, P
Source: Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery - Category: Cardiovascular & Thoracic Surgery Tags: Original Articles Source Type: research