The comparison of cement- and screw-retained crowns from technical and biological points of view.

CONCLUSIONS: The research of literature data for the last five years showed that screw-retained crowns demonstrated more failures such as porcelain cracks and fractures or screw loosening, while cement-retained crowns caused more severe biological complications such as peri-implant soft tissue inflammation or pathological bone resorption. PMID: 29243683 [PubMed - in process]