Denoising of dynamic PET images using a multi-scale transform and non-local means filter

In this study, we present a new method based on multi-scale and non-local means method (MNLM) to reduce noise in dynamic PET sequences of small animal heart. MNLM filter takes into account the temporal correlation between images in the dynamic measurement and benefits from the complementary properties of both the Shearlet transform and the wavelet transform to provide best reduction. The method was tested on dynamic digital mouse phantom and a preclinical rat study (n =6). Based on a comparative study with three major algorithms reviewed on the state of the art, the data analysis proved the significance of the MNLM filter. In simulated data, the major finding of the study showed that at the highest noise level (7.68%), the model gave the best result (Chi-square=4.06). Furthermore, it presented a notable gain in terms of PSNR and SSIM plot. In real data, the MNLM showed a better result in the computation of the contrast metric with a value of 27.04∓12.1 and the highest SNR with a value of 74.38∓9.2. This approach proved a better potential and could be considered as a valuable candidate to reduce noise in clinical system.
Source: Biomedical Signal Processing and Control - Category: Biomedical Science Source Type: research