Biomechanical Comparison Study of Three Fixation Methods for Proximal Chevron Osteotomy of the First Metatarsal in Hallux Valgus.
Conclusions: Authors have demonstrated proximal chevron metatarsal osteotomy with intramedullary screw fixation provides superior biomechanical stability to locking plate and K-wire fixations. The new technique using intramedullary screw fixation can offer robust fixation and may lead to better outcomes in surgical treatment of hallux valgus.
PMID: 29201305 [PubMed - in process]
Source: Clinics in Orthopedic Surgery - Category: Orthopaedics Tags: Clin Orthop Surg Source Type: research