Evaluation of pre-analytical conditions and comparison of the performance of several digital PCR assays for the detection of major EGFR mutations in circulating DNA from non-small cell lung cancers: the CIRCAN_0 study.

Evaluation of pre-analytical conditions and comparison of the performance of several digital PCR assays for the detection of major EGFR mutations in circulating DNA from non-small cell lung cancers: the CIRCAN_0 study. Oncotarget. 2017 Oct 20;8(50):87980-87996 Authors: Garcia J, Dusserre E, Cheynet V, Bringuier PP, Brengle-Pesce K, Wozny AS, Rodriguez-Lafrasse C, Freyer G, Brevet M, Payen L, Couraud S Abstract Non invasive somatic detection assays are suitable for repetitive tumor characterization or for detecting the appearance of somatic resistance during lung cancer. Molecular diagnosis based on circulating free DNA (cfDNA) offers the opportunity to track the genomic evolution of the tumor, and was chosen to assess the molecular profile of several EGFR alterations, including deletions in exon 19 (delEX19), the L858R substitution on exon 21 and the EGFR resistance mutation T790M on exon 20. Our study aimed at determining optimal pre-analytical conditions and EGFR mutation detection assays for analyzing cfDNA using the picoliter-droplet digital polymerase chain reaction (ddPCR) assay. Within the framework of the CIRCAN project set-up at the Lyon University Hospital, plasma samples were collected to establish a pre-analytical and analytical workflow of cfDNA analysis. We evaluated all of the steps from blood sampling to mutation detection output, including shipping conditions (4H versus 24H in EDTA tubes), the reproducibility of cfDN...
Source: Oncotarget - Category: Cancer & Oncology Tags: Oncotarget Source Type: research