A robust QRS complex detection using regular grammar and deterministic automata

Publication date: February 2018 Source:Biomedical Signal Processing and Control, Volume 40 Author(s): Salah Hamdi, Asma Ben Abdallah, Mohamed Hedi Bedoui A novel approach is proposed for medical analysis and clinical decision support of the Electrocardiogram (ECG) signals based on the deterministic finite automata (DFA) with the addition of some requirements. This paper proves regular grammar is effective in the extraction of QRS complex and interpretation of ECG signals. The DFA will be used to represent a normalized QRS complex as a sequence of negative and positive peaks. A QRS is considered as a set of adjacent peaks that satisfy certain criteria of standard deviation and duration. The proposed method is applied on several kinds of ECG signals collected from the standard MIT-BIH arrhythmia database. Several metrics are calculated including QRS durations, RR distances and peak amplitudes. Furthermore, σRR and σQRS metrics were added to quantify RR distances regularity and QRS durations, respectively. Regular grammar with the addition of some requirements and deterministic automata proved functional for both biomedical signals and ECG signal diagnosis. The suggested method provided a sensitivity rate of 99.74% and the positive predictivity rate of 99.86%. The algorithm was compared to other works in the literature and the quality performance detection was compared with several algorithms tested and validated on the MIT-BIH database. A head-to-head comparison in terms...
Source: Biomedical Signal Processing and Control - Category: Biomedical Science Source Type: research