A Biomimetic Alternative to Synthetic Hydroxyapatite: “Boron-Containing Bone-Like Hydroxyapatite” Precipitated From Simulated Body Fluid

Background: Biological hydroxyapatite (HA), has several mechanical and physical advantages over the commercially available synthetic apatite (CAP-HA). The aim of this in vivo study was to investigate the effect of osteoinductive “bone-like hydroxyapatite” obtained from simulated body fluid (SBF) combined with osteoinductive “boron” (B) on bone healing. Materials: Bone like nanohydroxyapatite (SBF-HA) was precipitated from 10× simulated body fluid (10×SBF). Thirty Sprague-Dawley rats were randomly divided into 5 experimental groups (n = 6 each). The groups were involving blank defect, chitosan, SBF-HA, SBF-HA/B, and CAP-HA. Two biparietal round critical sized bone defect was created using a dental burr. The rats were sacrificed respectively at the end of second and fourth months after surgery and their calvarium were harvested for further macroscopic, microtomographic, and histologic evaluation. Results: The SBF-HA/B group demonstrated the highest mineralized matrix formation rates (30.69 ± 3.73 for the second month, 62.68 ± 7.03 for the fourth month) and was significantly higher than SBF-HA and the CAP-HA groups. The SBF-HA/B group demonstrated the highest mineralized matrix formation rates (30.69 ± 3.73 for the second month, 62.68 ± 7.03 for the fourth month) and was significantly higher than SBF-HA and the CAP-HA groups. In means of bone defect repair histologically, the highest result was observed in the SBF-HA/B group (P
Source: Annals of Plastic Surgery - Category: Cosmetic Surgery Tags: Transplantation Surgery and Research Source Type: research