Scout-Based Automated Tube Potential Selection Technique (kV Assist) in Enhanced Chest Computed Tomography: Effects on Radiation Exposure and Image Quality

Objective: The aim of our study was to assess radiation dose reduction and image quality for enhanced chest CT examinations with a scout-based automated tube potential selection technique (kV Assist) compared with a standard 120-kV protocol. Methods: Prospective study of enhanced chest CT examinations was performed in 100 consecutive patients with kV Assist and in 100 consecutive patients with conventional 120-kV protocol on a multislice CT (Discovery CT750 HD). The body mass index, CT dose index volume, and dose length product were recorded from the examination protocol. Image noise and CT value was measured on region of interest, signal-to-noise ratio, and contrast-to-noise ratio was calculated. The subjective image quality was assessed by two radiologists blinded to the respective protocol with the use of a 3-grade scale (3, superior quality; 2, moderate quality; 1, inferior quality). Results: With kV Assist, the percentages of patients being scanned using 80, 100, and 120 kV were 12.0%, 80.0%, and 8.0%, respectively. The kilovolt setting was related with body mass index (r = 0.565, P = 0.000). Compared with the conventional 120 kV protocol, kV Assist allowed for an overall average decrease of 30.6% in CT dose index volume (kV Assist, 11.05 ± 4.78 mGy; 120 kV, 15.92 ± 6.89 mGy) (P
Source: Journal of Computer Assisted Tomography - Category: Radiology Tags: Thoracic Imaging Source Type: research