The effect of pre-operative topical anaesthetic cream on the ablative width and coagulative depth of ablative fractional resurfacing laser

The objective of the study was to compare the ablative width (AW) and coagulative depth (CD) of AFR laser with and without pre-treatment with TAC. Four Thai females who underwent abdominoplasty were included in the study. The excised skin of each subject was divided into four areas. TAC (eutectic mixture of local anaesthesia; EMLA) with 1-h occlusion was applied only on the first and second areas. The first and third areas were treated with FCO2 at 15  mj and 5% density. The second and fourth areas were treated with FEr:YAG at 28 J/cm2 and 5% density. Six biopsied specimens were obtained from each area. A total of 96 specimens (24 specimens from each area) were collected from four patients and examined randomly by two dermatopathologists. The ablative width and coagulative depth from each specimen were determined. In FCO2-treated specimens, the mean AW of the specimens that were pre-treated with TAC and control was 174.86  ± 24.57 and 188.52 ± 41.32 μm. The mean CD of the specimens that were pre-treated with TAC and control was 594.96 ± 111.72 and 520.03 ± 147.40 μm. There were no significant differences in AW and CD between both groups (p = 0.53 andp = 0.15). In FEr:YAG-treated specimens, the mean AW of the specimens that were pre-treated with TAC and control was 381.11 ± 48.02 and 423.65 ± 60.16 μm. The mean CD of the specimens that were pre-treated with TAC and control was 86.03 ± 29.44 and 71.59 ± 18.99 μm. There w...
Source: Lasers in Medical Science - Category: Laser Surgery Source Type: research