Evaluation of dose-area product of common radiographic examinations towards establishing a preliminary diagnostic reference levels (PDRLs) in Southwestern Nigeria

In Nigeria, a large number of radiographic examinations are conducted yearly for various diagnostic purposes. However, most examinations carried out do not have records of doses received by the patients, and the employed exposure parameters used are not documented; therefore, adequate radiation dose management is hin ­dered. The aim of the present study was to estimate the dose-area product (DAP) of patients examined in Nigeria, and to propose regional reference dose levels for nine common examinations (chest PA, abdomen AP, pelvis AP, lumbar AP, skull AP, leg AP, knee AP, hand AP, and thigh AP) undertaken in N igeria. Measurement of entrance surface dose (ESD) was carried out using thermoluminescent dosimeter (TLD). Measured ESDS were converted into DAP using the beam area of patients in 12 purposely selected hospitals. Results of the study show that the maximum/ minimum ratio ranged from 3 for thigh AP t o 57 in abdomen AP. The range of determined mean and 75th percentile DAPs were 0.18–17.16, and 0.25–28.59 Gy cm2, respectively. Data available for comparison show that 75th percentile DAPs in this study (in chest PA, abdomen AP, pelvis AP, lumbar AP) are higher than NRPB-HPE reference values. Th e DAP in this study is higher by factor of 31.4 (chest PA), 9.9 (abdomen AP), 2.2 (pelvis AP), and 2.1 (lumbar AP) than NRPB-HPE values. The relative higher dose found in this study shows nonoptimization of practice in Nigeria. It is expected that regular dose auditing and dose...
Source: Journal of Applied Clinical Medical Physics - Category: Physics Source Type: research