Percutaneous Pulmonary Valve Implantation Alters Electrophysiologic Substrate [Pediatric Cardiology]

The objective of this study is to assess the short‐ and medium‐term electrophysiologic substrate changes and elucidate postprocedure arrhythmias.Methods and ResultsA retrospective chart review of patients undergoing PPVI from May 2010 to April 2015 was performed. A total of 106 patients underwent PPVI; most commonly these patients had tetralogy of Fallot (n=59, 55%) and pulmonary insufficiency (n=60, 57%). The median follow‐up time was 28 months (7‐63 months). Pre‐PPVI, 25 patients (24%) had documented arrhythmias: nonsustained ventricular tachycardia (NSVT) (n=9, 8%), frequent premature ventricular contractions (PVCs) (n=6, 6%), and atrial fibrillation/flutter (AF/AFL) (n=10, 9%). Post‐PPVI, arrhythmias resolved in 4 patients who had NSVT (44%) and 5 patients who had PVCs (83%). New arrhythmias were seen in 16 patients (15%): 7 NSVT, 8 PVCs, and 1 AF/AFL. There was resolution at medium‐term follow‐up in 6 (86%) patients with new‐onset NSVT and 7 (88%) patients with new‐onset PVCs. There was no difference in QRS duration pre‐PPVI, post‐PPVI, and at medium‐term follow‐up (P=0.6). The median corrected QT lengthened immediately post‐PPVI but shortened significantly at midterm follow‐up (P
Source: JAHA:Journal of the American Heart Association - Category: Cardiology Authors: Tags: Arrhythmias, Electrophysiology, Pediatrics, Congenital Heart Disease, Treatment Original Research Source Type: research