Systematic Evaluation of Amide Proton Chemical Exchange Saturation Transfer at 3 T: Effects of Protein Concentration, pH, and Acquisition Parameters

Conclusions: Amide proton transfer–CEST imaging is a highly reproducible method in which absolute signal differences of approximately 0.5% are detectable in principle. For in vivo applications, Fourier or sSpline interpolations of z-spectra are preferable. Using reduced data sets delivers similar results but with increased variation and therefore decreased (pH/concentration) differentiation capability. Differentiation capability increases with increases in the saturation duration and power level. The results from the in vitro BSA system cannot be directly transferred to the in vivo situation due to different chemical environments resulting in, for example, higher asymmetric macromolecular cMT effects in vivo. Amine signals from small molecules are unlikely to contribute to APT-CEST at 3 T (except for creatine); however, signals can be enhanced by using short saturation times and higher power levels.
Source: Investigative Radiology - Category: Radiology Tags: Original Articles Source Type: research