Cochlear implantation in the mouse via the round window: Effects of array insertion.

Cochlear implantation in the mouse via the round window: Effects of array insertion. Hear Res. 2014 Mar 18; Authors: Mistry N, Nolan LS, Saeed SR, Forge A, Taylor RR Abstract Animal models are the only means of assessing the effects of cochlear implantation (CI) at a cellular and molecular level. The range of naturally occurring and genetically-modified mouse strains which mimic human deafness provide excellent opportunities for auditory research. To date, there are very few studies of CI in mice. The main aims of this study were to develop a reproducible and viable technique to enable long term CI in the mouse and to assess the response of the mouse cochlea to implantation as a means of evaluating the success of the procedure. Electrode array implantation via the round window was performed in C57Bl/6 mice aged 3 and 6 months. The contralateral cochlea acted as a control. Auditory brainstem responses (ABR) were recorded prior to and following CI. Analysis showed greater threshold shifts in the implanted ear compared to the control ear post-implantation, but substantial preservation of hearing. There were no cases in which implantation caused a profound hearing loss across all frequencies. Cone beam computerised tomography and light microscopy confirmed correct placement of the electrode array within the scala tympani. Cochleae were prepared for histological examination. Initial analysis revealed encapsulation of the implant in tissue with mor...
Source: Hearing Research - Category: Audiology Authors: Tags: Hear Res Source Type: research