Analysis of the pre-analytical phase in a private pathology laboratory of Maringá city-PR, Brazil

Conclusion: The pre-analytical phase represented 70.8% of the orders for new collection. According to the reports from the Quality Control Database, the most frequent reason of recollection in the preanalytical phase was insufficient sample volume (58.54%), followed by clotted sample (19.29%), hemolyzed sample (9.43%), incorrect labeling of sample (8.21%), lipemic sample (3%) and improper sample (1.56%). Although the results of nonconformity forms presented different records, both clearly point to problems in collection and patient registration sector, sustaining that the main problems of clinical laboratories arise from the failure in quality specifications for pre-analytical phase.RESUMO Introdução: A fase pré-analítica envolve a maior parte dos erros dos laboratórios de análises clínicas. Informações que caracterizem a ocorrência desses erros podem ser úteis para disponibilizar estratégias de prevenção e redução. Objetivo: O objetivo principal deste estudo foi identificar os principais erros na fase pré-analítica de um laboratório privado da cidade de Maringá-PR e sua frequência de ocorrência. Materiais e métodos: Foram coletados dados dos pedidos de recoleta de junho de 2013 a maio de 2015. Ao todo, foram cadastradas coletas de 707.449 exames; destes, 1.274 (0,18%) tiveram pedidos de nova coleta com base em algum critério adotado pelo laboratório. Conclusão: A etapa pré-analítica representou 70,80% dos pedidos de nova coleta. Segundo os rel...
Source: Jornal Brasileiro de Patologia e Medicina Laboratorial - Category: Pathology Source Type: research