Deformable image registration and interobserver variation in contour propagation for radiation therapy planning

Deformable image registration (DIR) and interobserver variation inevitably intro­duce uncertainty into the treatment planning process. The purpose of the current work was to measure deformable image registration (DIR) errors and interobserver variability for regions of interest (ROIs) in the head and neck and pelvic regions. Measured uncertainties were combined to examine planning margin adequacy for contours propagated for adaptive therapy and to assess the trade-off of DIR and interobserver uncertainty in atlas-based automatic segmentation. Two experi­enced dosimetrists retrospectively contoured brainstem, spinal cord, anterior oral cavity, larynx, right and left parotids, optic nerves, and eyes on the planning CT (CT1) and attenuation-correction CT of diagnostic PET/CT (CT2) for 30 patients who received radiation therapy for head and neck cancer. Two senior radiation oncology residents retrospectively contoured prostate, bladder, and rectum on the postseed-implant CT (CT1) and planning CT (CT2) for 20 patients who received radiation therapy for prostate cancer. Interobserver variation was measured by calculating mean Hausdorff distances between the two observers’ contours. CT2 was deformably registered to CT1 via commercially available multipass B-spline DIR. CT2 contours were propagated and compared with CT1 contours via mean Hausdorff distances. These values were summed in quadrature with interobserver variation for margin analysis and compared with interobserver var...