No role for tri-iodothyronine (T3) testing in the assessment of levothyroxine (T4) over-replacement in hypothyroid patients.

This study investigated how informative T3 levels are in these patients. Our hypothesis is that T3 measurement would not add anything to the assessment of T4 over-replacement in primary hypothyroidism. Over a 15-week period, consecutive thyroid function test requests in patients on levothyroxine had T3 levels measured if thyroid-stimulating hormone (TSH) was below the reference range (RR; <0.27 miu/L) and free T4 was within or above the RR (12-22 pmol/L). Those with fully suppressed TSH (<0.02 mu/L) and high free T4 (>27 pmol/L) were defined as being over-replaced, while those with low, but measurable TSH and a normal free T4 were defined as unlikely to be over- replaced (control group). Receiver operating characteristic (ROC) curve analysis was used to assess the discriminant power of T3 to detect over-replacement. Of the 542 patients examined, 33 were included in the over-replaced group and 236 patients in the control group. A total of 273 patients were excluded for not fulfilling the criteria for either of these groups. In the over-replaced group, none had a raised T3. The most discriminant T3 level, using ROC curve analysis, was 1.6 nmol/L (RR=1.3-2.6 nmol/L), with a corresponding sensitivity and specificity of 58% and 71%, respectively (P=0.16). T3 levels bear little relation to thyroid status in patients on levothyroxine replacement, and normal levels can be seen in over-replaced patients. Measurement of T3 in this situation is of doubtful clinical value. WHAT'...
Source: British Journal of Biomedical Science - Category: Laboratory Medicine Tags: Br J Biomed Sci Source Type: research