Replacement of the aortic valve with a bioprosthesis at the time of continuous flow ventricular assist device implantation for preexisting aortic valve dysfunction.

Replacement of the aortic valve with a bioprosthesis at the time of continuous flow ventricular assist device implantation for preexisting aortic valve dysfunction. Proc (Bayl Univ Med Cent). 2015 Oct;28(4):454-6 Authors: Lima B, Chamogeorgakis T, Mountis M, Gonzalez-Stawinski GV Abstract Left ventricular assist device (LVAD) implantation has become a mainstay of therapy for advanced heart failure patients who are either ineligible for, or awaiting, cardiac transplantation. Controversy remains over the optimal therapeutic strategy for preexisting aortic valvular dysfunction in these patients at the time of LVAD implant. In patients with moderate to severe aortic regurgitation, surgical approaches are center specific and range from variable leaflet closure techniques to concomitant aortic valve replacement (AVR) with a bioprosthesis. In the present study, we retrospectively analyzed our outcomes in patients who underwent simultaneous AVR and LVAD implantation secondary to antecedent aortic valve pathology. Between January 2004 and June 2010, 144 patients underwent LVAD implantation at a single institution. Of these, 7 patients (4.8%) required concomitant AVR. Five of the 7 patients (71%) survived to hospital discharge and suffered no adverse events in the perioperative period. One-year survival for the discharged patients was 80%, and no prosthetic valve-related adverse events were observed in long-term follow-up. Given our experience...