Determination of protamine and heparin based on their effects on a glucose oxidase enzymatic reaction

Anal Sci. 2023 May 27. doi: 10.1007/s44211-023-00373-x. Online ahead of print.ABSTRACTThis paper describes a sensitive method for determining protamine and heparin by utilizing a glucose oxidase enzymatic reaction. Polycationic protamine significantly promoted the enzymatic reaction rate with [Fe(CN)6]3-, so that the increase could be used to determine protamine. The promotion effect was stoichiometrically decreased by the addition of polyanionic heparin through the polyion complex formation with protamine, so that the enzymatic reaction also allowed for the determination of heparin. We thus applied the proposed method to blood plasma containing heparin and found that heparin did not stoichiometrically form a polyion complex with protamine, likely due to strong interactions between heparin and some components of the plasma. The proposed method allowed for the detection of free protamine (and/or weakly binding protamine with heparin) existing in the condition that protamine did not neutralize all of the heparin in the plasma. The method also permitted for the estimation of heparin concentrations using calibration curves. Thus, the proposed method would help reduce the risks of protamine overdose in heparin neutralization and would be a helpful tool in clinical practices that use heparin and protamine.PMID:37243969 | DOI:10.1007/s44211-023-00373-x
Source: Analytical Sciences : the international journal of the Japan Society for Analytical Chemistry - Category: Chemistry Authors: Source Type: research